- Downloads
res_fax: check_modem_rate() returned incorrect rate for V.27
According to the new standard for V.27 and V.32 they are able to transmit at a bit rate of 4,800 or 9,600. The check_mode_rate function needed to be updated to reflect this. Also, because of this change the default 'minrate' value was updated to be 4800. (closes issue ASTERISK-22790) Reported by: Paolo Compagnini Patches: res_fax.txt uploaded by looserouting (license 6548) ........ Merged revisions 405656 from http://svn.asterisk.org/svn/asterisk/branches/1.8 ........ Merged revisions 405693 from http://svn.asterisk.org/svn/asterisk/branches/11 ........ Merged revisions 405694 from http://svn.asterisk.org/svn/asterisk/branches/12 git-svn-id: https://origsvn.digium.com/svn/asterisk/trunk@405695 65c4cc65-6c06-0410-ace0-fbb531ad65f3